RT60

Also known as: reverberation time

On this page 8

RT60 is the reverberation time of a space: the time, in seconds, that sound energy needs to decay by 60 decibels after the source stops. In audio work and room Acoustics, it is the single most widely quoted number for describing how live or dry a room sounds, and it guides decisions about recording rooms, control rooms, concert halls, classrooms and offices.

A decay of 60 dB means the sound pressure level falls to one millionth of its original intensity, roughly the point where a loud event becomes inaudible against a quiet background. Because RT60 summarizes the combined effect of room volume and surface absorption, it is a practical bridge between the physics of reverberation and the everyday judgment of whether a room is suitable for speech, music or monitoring.

How RT60 is defined and measured

RT60 is measured by exciting a room with sound and recording how the level falls once the excitation ends. Practitioners plot the energy decay curve and read the slope, expressed in decibels per second, then extrapolate it to a full 60 dB drop. The standard procedure is described in ISO 3382, which covers performance spaces, ordinary rooms and open-plan offices.

A full 60 dB of clean decay is rarely available above the background noise, so measurements usually use a shorter range. T20 fits the decay between -5 dB and -25 dB and multiplies the time by three; T30 fits -5 dB to -35 dB and multiplies by two. A closely related measure, early decay time (EDT), uses the first 10 dB and correlates better with perceived reverberance.

The excitation signal determines measurement quality. Impulsive sources are quick but noisy, while swept-sine and MLS signals produce a clean impulse response from which the decay curve is derived by Schroeder backward integration. The table below compares the common methods.

MethodExcitationStrengthWeakness
Interrupted noisePink noise switched offSimple, robustRequires averaging several decays
Balloon or starter pistolImpulseFast, portablePoor repeatability and low-frequency energy
Exponential sine sweepSwept toneHigh signal-to-noise ratioSensitive to movement during the sweep
MLS sequencePseudo-random noiseGood noise rejectionSensitive to distortion and time variance
Common RT60 measurement methods

The Sabine and Eyring equations

RT60 can be predicted before construction with simple formulas. Wallace Sabine established that reverberation time is proportional to room volume and inversely proportional to total absorption. In metric units the Sabine equation is RT60 = 0.161 V / A, where V is the volume in cubic meters and A is the total absorption in metric sabins, the sum of each surface area multiplied by its absorption coefficient.

Sabine’s formula assumes a diffuse sound field and works well in fairly live rooms with average absorption coefficients below about 0.2 to 0.3. In heavily treated rooms it overestimates the time, so the Eyring equation, which uses a logarithmic term for absorption, gives more realistic values. Neither formula handles uneven absorption well, which is why designers increasingly use ray-tracing and image-source simulation.

ApproachBest suited toMain limitation
Sabine equationLive rooms, early design estimatesOverestimates RT60 in absorbent rooms
Eyring equationRooms with higher average absorptionStill assumes a diffuse field
Fitzroy and Arau-PuchadesRooms with absorption concentrated on some surfacesEmpirical, less widely validated
Geometric simulationComplex shapes, final design checksAccuracy depends on input data and low-frequency modeling
Prediction approaches compared

Frequency dependence of reverberation time

RT60 is not a single value for a real room, because absorption varies strongly with frequency. Measurements are therefore reported in octave or third-octave bands, typically from 125 Hz to 4 kHz. Thin porous panels absorb high frequencies efficiently but do little below 250 Hz, so many rooms show a long low-frequency tail and a short treble decay.

A balanced room keeps the curve reasonably flat across bands, often allowing a modest rise at low frequencies in music halls to add warmth. In small rooms below roughly 200 Hz, behavior is dominated by room modes rather than a statistical decay, and a single RT60 figure there can be misleading; modal ringing at specific frequencies matters more than the averaged time.

Single-number summaries such as T mid, the average of the 500 Hz and 1 kHz bands, are convenient for specifications but should always be read alongside the full band data.

Typical RT60 targets by room type

The appropriate RT60 depends on room purpose and volume. Speech needs short decay for intelligibility, while orchestral and choral music benefits from longer decay that blends notes. The ranges below are typical mid-frequency targets; larger rooms generally tolerate longer times.

Room typeTypical RT60Priority
Recording control room0.2-0.4 sAccurate monitoring
Vocal booth0.1-0.3 sDry, uncolored capture
Classroom0.4-0.7 sSpeech intelligibility
Home theater0.3-0.5 sClear dialogue and imaging
Concert hall1.8-2.2 sEnvelopment and blend
Large cathedral4-8 s or moreLiturgical music, not speech
Typical mid-frequency RT60 ranges

Building codes and design guides in many countries set maximum reverberation times for schools and healthcare spaces, because excessive decay raises noise levels and fatigue. Designers usually aim for the lower end of a range when a room must serve speech and amplified sound.

Controlling RT60 with acoustic treatment

Reducing RT60 means adding absorption in the right frequency bands. Porous absorbers such as mineral wool panels handle mid and high frequencies, while bass traps, membrane absorbers and Helmholtz resonators target low frequencies. Increasing RT60 is achieved by removing absorption or adding volume, and diffusers can make a decay sound more even without changing its length much.

SymptomLikely causeRemedy
Boomy low endLong low-frequency RT60, room modesThick bass traps in corners
Dull, lifeless soundToo much thin high-frequency absorptionReplace foam with broadband panels or diffusers
Poor speech clarityOverall RT60 too longAbsorptive ceiling and wall panels
Flutter echoParallel reflective surfacesAbsorb or diffuse one surface of each pair
Common RT60 problems and remedies

A common mistake is treating RT60 as the only goal. A room can meet its target and still suffer from strong early reflections, flutter echo or modal peaks, so experienced acousticians combine RT60 with clarity metrics such as C50 and C80, and with listening tests.

Limitations and common misconceptions

  • RT60 is not echo. An echo is a distinct, delayed repetition; reverberation is a dense, continuous decay.
  • Soundproofing does not lower RT60. Isolation stops sound passing between spaces, while absorption shortens decay within a space.
  • One number is rarely enough. Band values, EDT and clarity indices reveal problems an average hides.
  • Small rooms defy statistics. Below the Schroeder frequency, modal behavior dominates and RT60 loses meaning.
  • Occupancy matters. An audience adds substantial absorption, so empty-room and occupied RT60 can differ noticeably.

In everyday language

RT60 tells you how long a room keeps ringing after a sound stops. Clap your hands in a stone church and the sound hangs in the air for several seconds. Clap in a bedroom full of furniture and it disappears almost at once. RT60 puts a number on that difference.

The key idea is simple: hard, empty, large rooms ring longer, and soft, furnished, small rooms ring less. Too much ringing makes speech muddy, while too little can make music feel flat. Good rooms have the right amount for their purpose.

Seen in the real world

A small production company converts a 40 cubic meter spare room with plaster walls and a wooden floor into a voice-over studio. An exponential sweep measurement shows an RT60 of about 0.9 s at 500 Hz and nearly 1.3 s at 125 Hz, and test recordings sound hollow and roomy.

The engineer installs 10 cm mineral wool panels on the side walls and ceiling, adds corner bass traps and places a rug on the floor. A second measurement shows about 0.25 s at mid frequencies and 0.4 s at 125 Hz. Narration now sounds close and clean, and editors no longer need to apply heavy noise and reverb reduction in post-production.